Product Details:
| Voltage | 24 V |
| Current | 25A |
| Output Voltage | 12 V DC |
| Usage/Application | Industrial Automation |
| Model Name/Number | 787-732 |
| Product Brand | Wago |
Product Details:
| Voltage | 24 V |
| Output Current | 10A |
| Usage/Application | Electronic Instruments |
| Product Brand | Wago |
| Model | 787-732 |
Product Details:
| Voltage | 24 V |
| Output Current | 20A |
| Usage/Application | Industrial Automation |
| Design | Smps |
| Display Type | LED |
| Phase | Single Phase |
Product Details:
| Voltage | 24 V |
| Current | 25A |
| Model Name/Number | 787-712 |
| Usage/Application | Commercial |
| Phase | Single Phase |
| Product Brand | Wago |
Product Details:
| Voltage | 24 V |
| Current | 25A |
| Usage/Application | Electronic Instruments |
| Phase | Single Phase |
| Model Name/Number | 787-712 |
| Product Brand | Wago |
Product Details:
| Current Rating | 500mA |
| Model Name/Number | 750-333 |
| Brand | Wago |
| Standard | EN 50170 |
| Communication | Profibus |
| Mounting Type | DIN-35 Rail |
The 750-333 Fieldbus Coupler maps the peripheral data of all the WAGO I/O System's I/O modules on PROFIBUS DP.
When initializing, the coupler determines the node's module structure and creates the process image of all inputs and outputs. Modules with a bit width smaller than eight are grouped in one byte for address space optimization.
It is furthermore possible to deactivate I/O modules and to modify the image of the node according to the connected signals without having to modify the existing control application.
The diagnostic concept is based on ID- and channel-related diagnostics according to EN 50170. This does away with the need for programming modules to evaluate manufacturer-specific diagnostic data.
Product Details:
| Number of Channels | 4 |
| Brand | Wago |
| Model Name/Number | 750-363 |
| Connection Technology | EtherNet/IPTM : 2 x RJ-45 |
| Product Mounting Type | DIN-35 Rail |
| Current Consumption | 350mA |
Product Details:
| Number of Channels | 4 |
| Model Name/Number | 750-403 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Product Brand | Wago |
Product Details:
| Number of Channels | 2 |
| Model Name/Number | 750-410 |
| Power | 24VDC |
| Accuracy | 0.75% |
| Frequency | 60Hz |
| Product Brand | Wago |
Product Details:
| Number of Channels | 4 |
| Model Name/Number | 750-415 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module receives control signals from field devices (e.g., sensors).
Each input has a bridge rectifier and capacitor and current limitation for AC/DC operation.
Each input module has a downstream noise-rejection filter with an integrated time constant.
Field and system levels are electrically isolated.
All inputs are isolated.
Product Details:
| Number of Channels | 2 |
| Model Name/Number | 750-421 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 55Hz |
| Product Brand | Wago |
This digital input module receives control signals from the field side and supplies a short-circuit proof voltage to the sensors. The module transfers the control signals and other information via a fieldbus coupler to the higher-level controller.
Each input module has a noise-rejection filter.
Each sensor can be supplied separately. A short circuit to ground is indicated as an error/fieldbus failure and a message is sent to the supervisory control.
The error is canceled automatically after it has been rectified.
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 2 |
| Model Name/Number | 750-425 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module receives control signals from NAMUR proximity sensors (per DIN EN 60947-5-6) from the field side.
Each channel of the sensors is supplied with a short-circuit-protected voltage of 8.2 V. A short circuit or a line break is indicated in the process image (1 bit) and via the red LED.
The green LED indicates the input status:
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 8 |
| Model Name/Number | 750-436 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module features eight channels in a width of just 12 mm (0.47 inch). It receives control signals from digital field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 4 |
| Model Name/Number | Wago |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 60Hz |
This digital input module receives control signals from field devices (e.g., sensors).
The module has four input channels and four 24 V outputs, providing a direct connection to four 2-wire sensors.
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 8 |
| Model Name/Number | 750-431 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module features eight channels in a width of just 12 mm (0.47 inch). It receives control signals from digital field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 2 |
| Model Name/Number | 750-400 |
| Power | 12V |
| Accuracy | 0.75% |
| Product Brand | Wago |
This digital input module receives control signals from field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Model Name/Number | 750-404 |
| Usage/Application | Laboratory |
| Brand | Wago |
| Number Of Digital Outputs | 2 |
| Signal Type | Voltage |
| Current Carrying Capacity | 10A |
This counter records 24 V binary pulses and transmits the counter status to the fieldbus system.
The U/D input allows either Up or Down counting.
Digital outputs DO 1 and DO 2 can be set using the control byte.
The control byte sets or resets the counter.
A counter lock-out is also possible.
Product Details:
| Number of Channels | 1 |
| Model Name/Number | 750-435 |
| Power | 24VDC |
| Accuracy | 0.5% |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module records binary signals from sensors operating in Zone 0+1 hazardous areas.
NAMUR sensors, optocouplers, mechanical contacts (in conjunction with resistance coupling module, available as an accessory) or other actuating elements can be connected via intrinsically safe devices.
The WAGO I/O System 750 must be installed either in Zone 2 or in a non-hazardous area.
Each sensor is supplied with a short-circuit-protected voltage of 8.2 V.
Indicators:
Field and system levels are electrically isolated.
Product Details:
| Model Name/Number | 750-377 |
| Brand | Wago |
| Total Current (System Supply) | 700 mA |
| Number Of Modules Per Node (Max.) | 64 |
| Communication | PROFINET IO |
| Bus Segment Length (Max.) | 100m |
This fieldbus coupler connects the WAGO I/O System 750 to PROFINET IO (open, real-time Industrial ETHERNET automation standard).
The coupler identifies the connected I/O modules and creates local process images for one I/O controller and one I/O supervisor according to preset configurations. This process image may include a mixed arrangement of analog (word-by-word data transfer) or complex modules and digital (bit-by-bit data transfer) modules.
The fieldbus coupler operates as an I/O device in the network. It features an integrated 2-port switch, simplifying the creation of a line structure without additional network components.
The device name can be assigned via DCP protocol or a default name can be instantiated via DIP switch.
Product Details:
| Number of Channels | 4 |
| Model Name/Number | 750-402 |
| Power | 24VDC |
| Accuracy | 0.75% |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module receives control signals from field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 2 |
| Model Name/Number | 750-401 |
| Power | 24VDC |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module receives control signals from field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 4 |
| Model Name/Number | 750-408 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Product Brand | Wago |
This digital input module receives control signals from field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Number of Channels | 8 |
| Model Name/Number | 750-430/040-000 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 60Hz |
| Product Brand | Wago |
This digital input module features eight channels in a width of just 12 mm (0.47 inch). It receives control signals from digital field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
The device is ideal for operation in extreme environments thanks to:
Product Details:
| Number of Channels | 8 |
| Model Name/Number | 750-430/025-000 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 55Hz |
| Product Brand | Wago |
This digital input module features eight channels in a width of just 12 mm (0.47 inch). It receives control signals from digital field devices (e.g., sensors).
Each input module has a noise-rejection filter.
Field and system levels are electrically isolated.
Product Details:
| Model Name/Number | 750-306 |
| Brand | Wago |
| Communication | DeviceNet |
| Bus Segment Length | 500 m |
| Current Consumption | 350mA |
This fieldbus coupler connects the WAGO I/O System as a slave to the DeviceNet fieldbus.
The fieldbus coupler detects all connected I/O modules and creates a local process image. Analog and specialty module data is sent via words and/or bytes; digital data is sent bit by bit.
The process image can be transferred via the DeviceNet fieldbus to the memory of the control system.
The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the DeviceNetTM to a control system for further processing. The process output data is sent via DeviceNetTM.
The data of the analog modules is stored in the process image that is created automatically according to the order in which the modules are connected to the coupler. The bits of the digital modules are sent byte by byte and added to the analog data. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.
Product Details:
| Current | 500mA |
| Model Name/Number | 750-307 |
| Brand | Wago |
| Communication | CANopen |
| Fieldbus segment Length Max | 1000 m |
This fieldbus coupler connects the WAGO I/O System as a slave to the CANopen fieldbus. Data is transmitted via PDOs and SDOs.
The fieldbus coupler detects all connected I/O modules and creates a local process image. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.
The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the CANopen bus to a control system for further processing. The process output data is sent via the CANopen bus.
The data of the analog modules is stored in the PDOs according to the order in which the modules are connected to the coupler. The bits from the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.
All entries of the object directory can be mapped as required in the five Rx PDOs and five Tx PDOs.
The complete input and output process image can be transmitted using SDOs.
Product Details:
| Current | 6mA |
| Frequency | 60Hz |
| Material | Polycarbonate |
| Model Name/Number | 750-338 |
| Brand | Wago |
This fieldbus coupler connects the WAGO I/O System as a slave to the CANopen fieldbus. Data is transmitted via PDOs and SDOs.
The fieldbus coupler detects all connected I/O modules and creates a local process image. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.
The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the CANopen bus to a control system for further processing. The process output data is sent via the CANopen bus.
The data of the analog modules is stored in the PDOs according to the order in which the modules are connected to the coupler. The bits of the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.
All entries of the object directory can be mapped as required in the 32 Rx PDOs and 32 Tx PDOs. The complete input and output process image can be transmitted using SDOs.
Spacer modules can be set via software.
Product Details:
| Current | 350mA |
| Model Name/Number | 750-338 |
| Brand | Wago |
| Communication | CANopen |
| Number Of SDOs | 2 SDO Servers |
This fieldbus coupler connects the WAGO I/O System as a slave to the CANopen fieldbus. Data is transmitted via PDOs and SDOs.
The fieldbus coupler detects all connected I/O modules and creates a local process image. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.
The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the CANopen bus to a control system for further processing. The process output data is sent via the CANopen bus.
The data of the analog modules is stored in the PDOs according to the order in which the modules are connected to the coupler. The bits of the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.
All entries of the object directory can be mapped as required in the 32 Rx PDOs and 32 Tx PDOs. The complete input and output process image can be transmitted using SDOs.
Spacer modules can be set via software.
Product Details:
| Current | 350mA |
| Model Name/Number | 750-340 |
| Brand | Wago |
| Communication | PROFINET IO |
| Number Of Modules Per Node Max | 64 |
This fieldbus coupler connects the WAGO I/O System to PROFINET IO, the open Industrial ETHERNET automation standard.
The fieldbus coupler detects all connected I/O modules and creates a local process image. This process image may include a mixed arrangement of analog (word-by-word data transfer) and digital (bit-by-bit data transfer) modules.
The fieldbus coupler is integrated into the application as a PROFINET IO device.
Product Details:
| Current | 350mA |
| Model Name/Number | 750-346 |
| Brand | Wago |
| Communication | DeviceNet |
| Number Of Fieldbus Nodes On Master | 64 |
| Mounting Type | DIN-35 Rail |
| Color | Light Gray |
The ECO Fieldbus Coupler is designed for applications with a low data width in the process image. These are primarily applications that use digital process data or only low volumes of analog process data.
The system supply is provided directly by the coupler. The field supply is provided via a separate supply module.
The DeviceNet Fieldbus Coupler detects all connected I/O modules and creates a local process image.
The process image can be transferred via the DeviceNet fieldbus to the memory of the control system.
The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the DeviceNetTM to a control system for further processing. The process output data is sent via DeviceNetTM.
The data of the analog modules is stored in the process image that is created automatically according to the order in which the modules are connected to the coupler. The bits of the digital modules are sent byte by byte and added to the analog data. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.
Product Details:
| Current | 350mA |
| Model Name/Number | 750-347 |
| Brand | Wago |
| Node ID Distribution | DIP Switch |
| Communication | CANopen |
| Number Of Modules Per Node Max | 64 |
The ECO Fieldbus Coupler is designed for applications with a low data width in the process image. These are primarily applications that use digital process data or only low volumes of analog process data.
The system supply is provided directly by the coupler. The field supply is provided via a separate supply module.
The CANopen Fieldbus Coupler detects all connected I/O modules and creates a local process image.
The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the CANopen bus to a control system for further processing. The process output data is sent via the CANopen bus.
The data of the analog modules is stored in the PDOs according to the order in which the modules are connected to the coupler. The bits from the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.
All entries of the object directory can be mapped as required in the five Rx PDOs and five Tx PDOs.
The complete input and output process image can be transmitted using SDOs.
Spacer modules can be set via software.
Product Details:
| Current | 350mA |
| Model Name/Number | 750-375 |
| Brand | Wago |
| Communication | PROFINET IO |
| Bus Segment Length (Max.) | 100m |
| Number Of Modules Per Node (Max.) | 250 |
This fieldbus coupler connects the WAGO I/O System 750 to PROFINET IO (open, real-time Industrial ETHERNET automation standard).
The coupler identifies the connected I/O modules and creates local process images for maximum two I/O controllers and one I/O supervisor according to preset configurations. This process image may include a mixed arrangement of analog (word-by-word data transfer) or complex modules and digital (bit-by-bit data transfer) modules.
The fieldbus coupler operates as an I/O device in the network. It features an integrated 2-port switch, simplifying the creation of a line structure without additional network components.
The device name can be assigned via DCP protocol or a default name can be instantiated via DIP switch.
Product Details:
| Number of Channels | 8 |
| Model Name/Number | 750-439 |
| Power | 24VDC |
| Accuracy | 0.25% |
| Frequency | 60Hz |
| Product Brand | Wago |
Product Details:
| Output Type | Digital |
| Brand | Wago |
| Mounting Type | Panel Mount |
| Usage/Application | Automation |
| Model | 750-821 |
Product Details:
| Number of Channels | 2 |
| Brand | Wago |
| Usage/Application | Industrial |
| Model Name/Number | 750-454/000-200 |
| Signal Type | Current |
This analog input module processes standard 4–20 mA signals.
The input signal is electrically isolated and is transmitted with a resolution of 12 bits.
The internal system supply powers the module.
The input channels of the module are differential inputs.
The shield directly connects to the DIN-rail.
Product Details:
| Number of Channels | 2 |
| Brand | Wago |
| Usage/Application | Industrial |
| Model Name/Number | 750-454 |
| Signal Type | Current |
This analog input module processes standard 4–20 mA signals.
The input signal is electrically isolated and is transmitted with a resolution of 12 bits.
The internal system supply powers the module.
The input channels of the module are differential inputs.
The shield directly connects to the DIN-rail.
Product Details:
| Number of Channels | 4 |
| Brand | Wago |
| Usage/Application | IOT |
| Model Name/Number | 750-453 |
| Signal Type | Current |
This analog input module processes standard 0–20 mA signals.
The input signal is electrically isolated and is transmitted with a resolution of 12 bits.
The internal system supply powers the module.
The input channels of the module have a common ground potential.
Product Details:
| Number of Channels | 2 |
| Brand | Wago |
| Usage/Application | Industrial |
| Connection Technology | 8XCage Clamp |
| Mounting Type | DIN-35 Rail |
Product Details:
| Number of Channels | 8 |
| Brand | Wago |
| Usage/Application | Industrial |
| Network Type | 3G |
| Model Name/Number | 750-451 |
This analog input module directly connects to Pt or Ni resistance sensors.
Two-wire sensors can be connected.
The module automatically linearizes the entire temperature range. A sensor error (short circuit, wire break or out-of-measurement range) is indicated by a red LED. Unused channels can be deactivated.
The module can be configured via WAGO‐I/O‐CHECK or GSD files.
It features multiple setting options and high accuracy.
Product Details:
| Number of Channels | 4 |
| Brand | Wago |
| Usage/Application | Industrial |
| Network Type | 3G |
| Model Name/Number | 750-450 |
| Product Brand | Wago |
This analog input module directly connects to Pt or Ni resistance sensors and potentiometers.
Two-, three- or four-wire resistance sensors and three-wire potentiometers can be connected.
The module automatically linearizes the entire temperature range. A sensor error (short circuit, wire break or out-of-measurement range) is indicated by a red LED. Unused channels can be deactivated.
The module can be configured via WAGO‐I/O‐CHECK or GSD files.
It features multiple setting options and high accuracy.